Data Center Environments We Serve
Warehouse-Scale Power Resilience
Massive battery backup systems for hyperscale facilities with thousands of servers and MW-scale power demands.
Enterprise DC Power Protection
Custom-engineered battery backup for on-premise enterprise data centres.
Multi-Tenant Battery Infrastructure
Battery infrastructure for colocation providers serving multiple tenants with shared UPS systems.
Cloud Infrastructure Power Continuity
Battery backup for cloud infrastructure requiring geo-redundant, scalable power protection.
Failover & Recovery Power Assurance
Reliable backup power for disaster recovery sites requiring RPO/RTO-ready hot standby.
Distributed Power Backup for Edge Infrastructure
Compact, ruggedized battery solutions for edge nodes, remote sites, and micro-DCs requiring reliable local backup.
Purpose-Built Batteries for Data Center Demands
Two proven technologies, each optimized for specific data center applications.
| SPECIFICATION | VRLA BATTERIESValve-Regulated Lead Acid | WET CELL BATTERIESFlooded / Vented Lead Acid |
|---|---|---|
| Technology Type | Sealed, maintenance-free AGM/Gel | Flooded, vented electrolyte |
| Runtime | 8โ20 hours (optimized) | 20+ hours (extended) |
| Maintenance | Low โ annual inspections only | Regular electrolyte checks required |
| DC Application | UPS systems & short-term bridging | Long-duration critical backup |
| Space Requirements | Compact rack-mount or cabinet | Dedicated battery room required |
| Best For | Controlled environments, colo racks | Hyperscale, generator bridging |
Axion Solutions for Data Centers & Colocation
Battery Backup Systems
High-performance VRLA & Wet Cell for every DC tier
- High-performance VRLA and wet cell batteries for UPS and DC power plants
- Optimized runtime for controlled shutdowns or generator bridging
- Remote monitoring, preventive maintenance, and lifecycle management
Integration with UPS & Load Management
N+1 & 2N redundancy with seamless failover
- Support for N+1 and 2N redundancy architectures across all DC tiers
- Load balancing and seamless integration with generators and PDUs
- Coordination with UPS and DC power systems for continuous operation
Maintenance & Emergency Support
24/7 response with proactive lifecycle management
- Preventive maintenance programs, regular inspections, and battery testing
- Replacement planning and environmentally responsible battery disposal
- 24/7 emergency response and uptime assurance services
Zero Compromise on Safety & Standards
Electrical Safety
Battery Systems
Full compliance with National Electrical Code requirements for stationary battery installations.
Fire & Life Safety
Emergency Power
Stored energy equipment standards for emergency power systems in critical data center facilities.
Environmental
Battery Disposal
Environmentally responsible recycling and disposal programs for VRLA and wet cell batteries.
Quality Management
Operations
International quality management system certification ensuring consistent service excellence.
Uptime Standards
Tier Classification
Solutions aligned with Tier IโIV data center infrastructure standards for power redundancy.
Sustainability
Green Operations
Energy-efficient battery solutions and sustainable practices supporting enterprise ESG goals.
End-to-End Lifecycle Management
Site Assessment & Design
Evaluate power requirements, load analysis, and battery system architecture for your facility.
Battery Sourcing
VRLA and wet cell battery procurement optimized for your runtime and redundancy requirements.
Installation & Integration
Expert installation with UPS, DC power plants, generators, and PDU coordination.
Monitoring & Maintenance
Remote monitoring, preventive maintenance programs, and performance health checks.
Replacement & Disposal
Battery replacement planning and environmentally responsible recycling programs.
The Critical Power Partner Data Centers Trust
Industry-focused expertise
Mission-critical power systems specialists serving data centers, telecoms, healthcare, and industrial sectors.
Proven reliability
Trusted by consulting engineers, contractors, and end users across enterprise and public-sector environments.
Scalable solutions
Battery systems designed to grow with your facility, from single-site colos to multi-campus hyperscale deployments.
Compliance-ready
All solutions meet NEC, NFPA, ISO, EPA, and Uptime Institute standards for seamless regulatory compliance.
End-to-end support
From design and installation to monitoring, maintenance, and responsible lifecycle management โ we never stop.
Power Your Uptime
with Confidence
Whether you operate a single colocation site or a multi-facility data center, Axion delivers the reliability, redundancy, and compliance your infrastructure demands.
Design Your Power Solution
Tell us about your facility โ we'll build the right solution.